Roofing blog › Repairs
Repairs

Attic Ventilation Explained, With a Power Fan Install in Lansing

Hamstra Roofing January 1, 2019Updated October 28, 20267 min read

Attic ventilation is a simple loop: cool outside air comes in low at the soffits, and hot, damp air leaves high near the ridge. When that loop works, your attic stays close to the outdoor temperature, which protects the shingles in summer and the roof deck in winter. Here's how it works, which vents fit which roofs, and how we added a power fan to a Lansing home that was simply too hot.

The short version

  • Conventional vented attics need both intake (low, at the soffits or eaves) and exhaust (high, at or near the ridge). One without the other doesn't move air. Properly designed unvented attics are the exception.
  • The model code baseline is 1 square foot of net free vent area for every 150 square feet of attic floor, split between intake and exhaust.
  • Don't mix exhaust types on one attic. A power fan next to a ridge vent tends to pull air from the ridge instead of the soffits.
  • Signs of trouble: a hot upstairs, frost on attic nails in winter, ice dams, damp insulation and shingles that age early.

The call: “Our house is too hot”

It was summer, and a customer in Lansing called our office with a common complaint. The house was far too hot, they wanted some kind of ventilation, and they wanted relief. Judy in our office took the call, and we put together a few options for them: passive vents that work on their own, or an electric power fan.

A couple of quick questions narrowed it down. The homeowners chose a power fan, and we picked one that best matched the color of the shingles and flashing on their roof, so it wouldn't stick out from the street.

Our service technician scheduled a visit later that week, because a ventilation job always starts in the attic. Here's how the install went:

  1. Clear the shingles where the fan will sit, between two rafters.
  2. Cut the opening in the roof deck between the rafters.
  3. Drop the cable and electrical box down into the attic, then nail the fan down to the deck.
  4. Set the thermostat. We usually set it at the standard 118 degrees, so the fan kicks on when the attic gets hot, but we'll adjust it to your preference.
  5. Weatherproof the flange. A few cut pieces of ice and water shield and some new shingles set around the fan protect its flanges from rain.

That's it. No sales pitch: just the homeowners, us, and their problem.

How does attic ventilation work?

Hot air rises. A vented attic uses that to its advantage. Openings low on the roof, usually in the soffits under the overhang, let outside air in. Openings high on the roof, at or near the ridge, let warm air out. As the attic air warms, it rises and leaves through the top, pulling fresh air in at the bottom. Wind across the roof helps too.

That's the conventional vented attic, which is what most homes around here have. Some homes are built with an unvented (or “conditioned”) attic instead, with the insulation at the roof deck. A properly designed unvented assembly isn't supposed to have vents, so don't add them without understanding how that roof was built.

That airflow does two jobs, one for each season:

  • Summer: it carries off the heat that builds up under a sun-baked roof, which is hard on shingles and makes the rooms below harder to cool.
  • Winter: it carries off moisture that sneaks up from the house, before it can frost onto the roof deck. (That frost is behind the winter ceiling stains in our condensation guide.) It also helps keep the roof deck cold, which works against ice dams.

For the soffit air to reach the vents up top, it needs a clear path. Insulation stuffed into the eaves or a soffit painted shut stops the whole system. Baffles at the eaves hold the insulation back and keep a channel open.

How much ventilation does my roof need?

The International Residential Code, which most Chicago-area villages build their codes on, sets a baseline: 1 square foot of net free vent area for every 150 square feet of attic floor. It allows that to drop to 1 for every 300 under certain conditions, such as when the vents are balanced with 40 to 50% of the area up high near the ridge and the rest low at the eaves. The exact conditions depend on the code edition your village has adopted.

“Net free area” is the actual open space a vent lets air through, after the screens and louvers. Every vent is rated for it, so ventilation is something you calculate, not eyeball. A common rule of thumb in the trade is balance: roughly as much intake as exhaust, and never less intake than exhaust.

Upstairs too hot, or frost in the attic?

Our service tech will go up into the attic and tell you whether it’s ventilation, insulation or air leaks.

(815) 464-6644

Ridge vent, box vents or a power fan: which is better?

Exhaust typeHow it worksGood to know
Ridge ventA continuous slot along the peak, covered by a low capEven airflow along the whole roof; needs enough ridge length and good soffit intake
Box (“mushroom”) ventsStatic vents set near the top of the roofNo moving parts; common on hip roofs with short ridges
Power fanA thermostat-controlled electric fan that pushes attic air outMoves a lot of air on hot days; needs plenty of intake and a well-sealed attic floor

One rule applies to all three: use one type of exhaust per attic. Air takes the easiest path. A power fan near a ridge vent tends to suck air in through the ridge instead of pulling it from the soffits, so the bottom of the attic never gets flushed. Gibraltar Building Products, a major vent manufacturer, warns that mixing a power vent with a ridge vent can short-circuit the system and even pull weather in. When we add a power fan, we look at what's already on the roof.

Are power attic fans a good idea?

They can be the right tool, as in Lansing, where the homeowners wanted serious summer relief. But we'll be straight with you about the conditions:

  • The fan needs intake. Without enough soffit vents, it has to get its air from somewhere.
  • That somewhere can be your house. Energy researchers at Advanced Energy note that power attic ventilators can pull cooled air up from the living space through ceiling leaks, making the air conditioner work harder. In a leaky house with a gas water heater or furnace, a strong fan can even contribute to backdrafting. Sealing the attic floor first helps a lot, but it doesn't always eliminate that risk, so if you have gas appliances, have them checked for proper draft and keep working carbon monoxide alarms.
  • It's a summer tool. The thermostat keeps it off when the attic is cool, so in winter it behaves like a static vent.

For many homes, balanced soffit and ridge ventilation with a sealed attic floor does the job without a motor. For others, a fan makes sense. That's why we look in the attic before we recommend anything.

What are the signs of poor attic ventilation?

  • Upstairs rooms that stay hot long after sunset
  • Frost on nail tips or the underside of the roof deck in winter
  • Ice dams at the eaves
  • Damp or matted insulation, or a musty smell in the attic
  • Dark stains, mold or soft spots on the roof deck
  • Shingles curling, blistering or losing granules years too early

Ventilation problems don't stay in the attic. They show up as rotted plywood, which turns a reroof into a much bigger job. If you're seeing several of these, our guide to why roofs wear out early explains what that heat and moisture do to a roof over time.

We serve Lansing, South Holland and the rest of the south suburbs and northwest Indiana, along with our home base around Frankfort. Planning a new roof? We size the ventilation as part of every residential reroof, using vents we trust, many of them made by a local family business.

Planning a new roof?

We’ll calculate intake and exhaust for your attic, not just swap the old vents for new ones.

Request an inspection

Questions we hear

What is the difference between intake and exhaust vents?

Intake vents, usually in the soffits under the overhang, let outside air into the attic low. Exhaust vents, at or near the ridge, let warm, moist air out high. A conventional vented attic needs both.

How much attic ventilation do I need?

The model residential code baseline is 1 square foot of net free vent area per 150 square feet of attic floor, which can drop to 1 per 300 when vents are balanced high and low under certain conditions. Your village's adopted code has the final say.

Can I have a power attic fan and a ridge vent?

It isn't recommended. Air takes the easiest path, so the fan tends to pull air in through the ridge vent instead of the soffits, short-circuiting the ventilation.

What temperature should an attic fan be set to?

Hamstra usually sets attic fan thermostats at the standard 118 degrees and adjusts to the homeowner's preference.

Do power attic fans save energy?

Not always. If the attic floor isn't well sealed, a fan can pull cooled air out of the house and make the air conditioner work harder. Seal ceiling air leaks first and make sure there is enough soffit intake.

The Hamstra Roofing team

Family-owned in Frankfort since 1978: estimators, service techs, crews and the office that keeps it all moving. Meet the team

Call (815) 464-6644