Ice and Water Shield: What Code Requires, and Why We Go Further

Hamstra Roofing December 4, 2024Updated October 28, 20264 min read

Watch the video

Ice and water shield is a sticky, rubberized membrane that goes under your shingles at the edge of the roof, where ice dams back water uphill. The building code sets a minimum for how far up the roof it has to run. At Hamstra, we also fold it down over the fascia and tuck it under the gutter, so it stops water from an ice dam that forms in the gutter itself, not just one that forms on the shingles.

The short version

  • Code calls for an ice barrier from the roof edge to at least 24 inches inside the exterior wall, measured horizontally, in areas with a history of ice dams.
  • That 24 inches is measured inside the wall line, so on most roofs the membrane has to run well past one 36-inch roll up the slope.
  • Hamstra wraps the membrane down over the subfascia, under the gutter and the gutter apron, to block ice dams that start in the gutter.
  • Code is the minimum. Above it are the manufacturer's specs, and above those are best practices. That's where we aim.

What is ice and water shield?

It's a self-adhering membrane, usually a polymer-modified bitumen sheet, that bonds to the roof deck and seals around every nail driven through it. Ordinary underlayment sheds water running downhill. Ice and water shield is built for water that's trying to run uphill: meltwater trapped behind a ridge of ice at the eaves, or rain driven sideways under shingles.

That's why it goes at the edges of the roof first. As our Roofing Basics guide explains, it's just as important around chimneys, in valleys and in small strips around vents.

What does the building code require?

Most Chicago-area villages base their residential building code on the International Residential Code. Its ice barrier rule (section R905.1.2) says that where there's a history of ice forming along the eaves, the roof needs either two layers of underlayment cemented together or a self-adhering polymer-modified bitumen sheet. It has to run from the lowest edge of the roof to a point at least 24 inches inside the exterior wall line of the house.

Two details catch people out:

  • It's measured horizontally, inside the wall. Add your overhang and the slope of the roof, and the membrane often has to run four feet or more up the roof. One trade example works out to about 47 inches up the slope on a 6:12 roof with a 12-inch overhang.
  • Your village has the final word. Communities decide whether ice barriers are required and can amend the details. Around Chicago, ice dams are a fact of winter, so plan on it.

Planning a new roof?

Ask us exactly how far up your roof the ice and water shield will go, and where it ends at the gutter.

Request an inspection

Why Hamstra goes beyond code at the gutter

Here's the detail we show in the video. Code-minimum installs put the ice and water shield on top of the gutter apron, the strip of metal that directs water into the gutter. That's practical: it means the gutters don't have to come off on every reroof.

We take a different approach when we can. We let the membrane hang past the shingles, fold it down over the subfascia, set the gutter over it, and put the gutter apron on top. We call it the belt-and-suspenders approach:

  • It protects against ice dams that start on the shingles and push water under them.
  • It also protects against ice dams that start in a frozen, packed gutter, where water backs up behind the gutter and finds its way into the fascia and wall.
“It's not to code. It's better.”From the video, after the village code enforcement officer looked it over and passed the inspection

Code, then specs, then best practice

We see roofing standards as three levels, each building on the one below:

  1. Building code: the legal minimum for safety. A roof that only meets code passes inspection.
  2. Manufacturer specifications: what the shingle maker requires for its warranty to hold. Often stricter than code.
  3. Best practices: what decades of fixing other people's roofs teaches you. Wrapping the ice barrier under the gutter lives here.

It's the same idea behind how we train our crews, which you can read about in Training Roofers: the gaping hole in our industry.

Ask any roofer you're comparingHow far up the roof does your ice and water shield go? Does it go over or under the gutter apron? Will you take the gutters off? The answers tell you a lot about how a roof was built, and how it will hold up in February.

See how our roofs look on homes near you.

Browse hundreds of Hamstra roofs by town and shingle color.

See roofs near you

Questions we hear

Is ice and water shield required by code in Illinois?

Most Chicago-area villages base their code on the International Residential Code, which requires an ice barrier in areas with a history of ice dams. Your village decides whether that applies and can amend the details, so check with its building department. Around Chicago, expect it to be required.

How far up the roof does ice and water shield have to go?

The model code requires it from the roof edge to at least 24 inches inside the exterior wall line, measured horizontally. Depending on the overhang and pitch, that often means four feet or more up the slope.

Should ice and water shield go over or under the gutter apron?

Code-minimum installs often put it over the gutter apron so gutters can stay in place. Hamstra prefers to fold it down over the subfascia and under the gutter and gutter apron, which also protects against ice dams that form in the gutter.

Does ice and water shield stop ice dams?

No. It doesn't stop ice from forming. It keeps the water an ice dam backs up from getting into your home. Preventing the dam itself comes down to attic insulation, air sealing and ventilation.

Where else should ice and water shield go?

Besides the eaves, it's commonly used in valleys, around chimneys and skylights, and in strips around vents and other roof penetrations.